What it tells you

Some problems never trip a breaker.

Insulation

Resistance slips every season

A steady fall matters more than any single reading.

Earthing

Protection you cannot see

An earth that looked fine on handover can corrode and dry out.

Supply

Dips, harmonics and unbalance

They make motors, drives and cables work harder and run hotter.

Everyday

Panels and circuits

Fast, safe checks with the right category of meter.

What we supply

Product groups

Tell us the job and we will recommend the model. No price lists here: the right instrument depends on the site.

FLIR CM276 thermal imaging clamp meter
Power

Multimeters and clamp meters

Everyday electrical measurement you can trust.

  • Fault finding on panels
  • Load and current checks
  • Commissioning

RangesFLIR DM and CM Series · Extech · Megger

Get a recommendation
Megger MIT series insulation resistance tester
Power

Insulation resistance testers

Catch failing insulation before it fails.

  • Motors and generators
  • Cables and switchgear
  • Routine and acceptance tests

RangesMegger MIT Series, from handheld testers to 15 kV

Get a recommendation
Megger DET earth tester with clamps
Power

Earth and ground testers

Prove your earthing really protects.

  • Earth electrode resistance
  • Soil resistivity
  • Lightning protection checks

RangesMegger DET range

Get a recommendation
Megger MPQ1000 power quality analyser
Power

Power quality analysers

See what the supply is really doing.

  • Harmonics, dips and swells
  • Unbalance and flicker
  • Week-long logging

RangesMegger MPQ Series · Extech

Get a recommendation

Some instruments need an export licence. We check before you order and tell you the timing.

Check a reading

Insulation result? Correct it to 40 °C.

Readings change with temperature, so compare like with like. Enter the reading and the winding temperature.

Open Field Companion
Insulation checkExample values
MΩ
°C
—MΩ at 40 °C
Correction factor
—
Minimum
—
—

—

Corrected with resistance halving for every 10 °C rise, as IEEE 43 allows for a quick check. Guidance for trained people; follow your site's safety rules and the full standard.

How we help

Test the same way every time.

Choose

Voltages and methods

We help you pick test voltages, durations and methods for each asset.

Train

Read the results

We show your team how to correct, compare and trend the readings.

Explain

A week of data

We explain what a week of power quality logging is telling you.

Questions

Questions people ask

If yours is not on the list, ask us. No question is too basic.

Most sites test on a fixed schedule, such as once a year or at each planned outage. What matters is the same voltage, duration and connections every time.

Insulation resistance roughly halves for every 10 °C rise, so a warm motor reads lower. Correcting to 40 °C lets you compare tests fairly.

It depends on whether you want to diagnose a problem now or watch the supply over time. Tell us the symptom and we will suggest one.

Talk to us about building A World Powered Well.